TM 9-2320-361-24-1
0016 00
0016 00-9
SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION ENGINE—REPROGRAMMABLE
(STE/ICE-R) TROUBLESHOOTING INTRODUCTION (Contd)
Table 3. Error Messages (Contd).
VTM
READOUT
INTERPRETATION
E024
Test is not valid for VID entered.
E027
Error in entry of compression unbalance constants.
E028
Test just entered cannot be used with control function 06.
E030
VID entered conflicts with speed transducer attached.
E032
Vehicle’s cranking speed is varying too much for a compression unbalance measurement.
E033
Error in entry of power test constants.
*Different STE/ICE vehicle connectors have different DCA numbers. You can find out what DCA
connector is connected by entering test 62. These error messages have a special meaning if connected
to DCA number 13 and message is displayed in response to a cylinder (CYL) or UEH (refer to table 2)
entry. In these cases, testing may continue, but the message is a warning that tests using CYL and
UEH information are normally performed with the VTM connected to a different connector in the
vehicle.