TM 9-2320-361-24-1
0015 00
0015 00-14
HEATING SYSTEMS TROUBLESHOOTING (Contd)
Table 1. Heating Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. HEATER CONTROL
BOX LIGHT
INOPERATIVE, BUT
HEATER OPERATIVE
Test 1. Check for voltage at heater
control box indicator lamp.
1. Set multimeter to a voltage
range that will measure
24 VDC.
2. Position heater control switch
to RUN.
3. Position heater switch to HIGH.
4. Remove heater control box
indicator lamp.
5. Touch positive lead of
multimeter to indicator lamp
socket.
6. Touch negative lead of
multimeter to frame ground.
Test 2. Check for voltage between
personnel heater and heater
control box.
1. Disconnect wiring harness
behind personnel heater
control box.
2. Connect jumper wire from pin
D to pin E at personnel
heater.
1. If voltage is present, replace
indicator lamp.
2. If voltage is not present, go to
test 2.
1. If heater control box indicator lamp
is lit, replace personnel heater
(WP 0351 00).
2. If indicator lamp fails to light,
repair or replace wiring harness
(WP 0090 00).
END OF WORK PACKAGE
INDICATOR
LAMP
HEATER
CONTROL BOX
PERSONNEL
HEATER
TEST 1
STEPS 5
AND 6
HARNESS
CONNECTOR