TM 9-2320-361-24-1
0015 00
0015 00-8
HEATING SYSTEMS TROUBLESHOOTING (Contd)
Table 1. Heating Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. HOT WATER
PERSONNEL HEATER
DOES NOT OPERATE
OR DOES NOT
OPERATE IN LOW
POSITION (Contd)
Test 4. Test personnel heater for
power input.
1 Ensure heater switch is in
high position.
2. Set multimeter to a range
that will measure 24 VDC.
3. Disconnect lead 400 from
personnel heater.
4. Touch multimeter positive
lead to contact end of lead
400.
5. Touch multimeter negative
lead to frame ground. Voltage
should be present.
Test 5. Test blower motor resistor.
1. Set multimeter to RX 1.
2. Ensure heater switch is set to
low position.
3. Touch positive lead of
multimeter to one lead on
resistor.
4. Touch negative lead of
multimeter to the other end
of resistor.
1. If voltage is not present, repair or
replace lead 400 (WP 0090 00).
2. If voltage is present, and personnel
heater fails to operate, replace
personnel heater (WP 0250 00).
If resistance is not within tolerance of
4.5 ohms and 5.5 ohms, replace
resistor (WP 0117 00).
TEST 4
STEPS 4
AND 5
LEAD
400