TM-9-2320-361-24-1

2-1/2 TON, 6X6, M44A2 SERIES TRUCKS

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE PART 1 OF 2

AUGUST 2006

  TM-9-2320-361-24-1 - Page 268 of 1176

TM 9-2320-361-24-1
0015 00
0015 00-12
HEATING SYSTEMS TROUBLESHOOTING (Contd)
Table 1. Heating Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. PERSONNEL FUEL
BURNING HEATER
INOPERATIVE
(Contd)
Test 4. Check for input power at fuel
pump.
1. Set multimeter to a range
that will measure 24 VDC.
2. Disconnect lead 25 at fuel
pump.
3. Touch multimeter positive
lead to contact end of lead 25.
4. Touch multimeter negative
lead to frame ground. Voltage
should be present.
Test 5. Check for power input at
personnel heater.
1. Set multimeter to a voltage
that will measure 24 VDC.
2. Disconnect harness connector
at personnel heater.
3. Set heater control switch to
the run position.
4. Touch multimeter positive
lead to pin A of harness
connector.
5. Touch multimeter negative
lead to frame ground.
6. Repeat steps 4 and 5 for pins
B, C, and D. Voltage should be
present at all pins tested.
1. If voltage is present, check fuel
pump for proper operation. Refer
to WP 0006 00, table 21,
malfunction 2, step 5.
2. If fuel pump is operating properly.
Go to test 5.
3. If voltage is not present, repair or
replace lead 25 (WP 0090 00).
1. If voltage is present, replace
personnel heater (WP 0351 00).
2. If voltage is not present at one or
more pins, repair or replace
harness connector (WP 0090 00).


Back to Top