TM 9-2320-361-24-1
0115 00
0115 00-1/2 blank
REMOVAL
NOTE
• Vehicle with auxiliary power outlets and personnel heaters
have two additional circuit breakers located next to horn
circuit breaker. Replacement procedures are the same for all
circuit breakers.
• Prior to removal, tag all lead wires for installation.
1.
Disconnect wires (1) and (5) from circuit breaker (2).
2.
Remove two screws (4) and circuit breaker (2) from firewall (3).
INSTALLATION
1.
Install circuit breaker (2) on firewall (3) with two screws (4).
2.
Connect wires (1) and (5) to circuit breaker (2).
3.
Connect battery ground cable (WP 0126 00).
4.
Lower and secure hood (TM 9-2320-361-10).
6.
Check operation of horn and personel heater (TM 9-2320-361-10).
7.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
FIELD MAINTENANCE INSTRUCTIONS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
CIRCUIT BREAKER REPLACEMENT
REMOVAL AND INSTALLATION
INITIAL SETUP:
Applicable Models
All
Equipment Condition
Parking brake set and wheels chocked
(TM 9-2320-361-10).
Hood raised and secured (TM 9-2320-361-10).
Battery ground cable disconnected
(WP 0126 00).
END OF WORK PACKAGE
~
1
2
3
4
5