TM-9-2320-361-24-2

2-1/2 TON, 6X6, M44A2 SERIES TRUCKS

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE PART 2 OF 2

AUGUST 2006

  TM-9-2320-361-24-2 - Page 893 of 1144

TM 9-2320-361-24-2
0435 00
0435 00-1
FIELD MAINTENANCE INSTRUCTIONS
FOR SPECIAL PURPOSE KITS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
FUEL BURNING PERSONNEL HEATER TESTING
PREPARATION, FLAME DETECTOR SWITCH TEST, FUEL CONTROL VALVE TEST, FLAME DETECTOR SWITCH TEST,
OVERHEAT SWITCH TEST, AND TEST EQUIPMENT REMOVAL
INITIAL SETUP:
Applicable Models
All
Tools and Special Tools
General mechanic’s tool kit
(item 116, WP 0469 00)
Multimeter (item 51, WP 0469 00)
Flowmeter
Test stand
Materials/Parts
Two nut-assembled lockwashers
(item 247, WP 0470 00)
References
WP 0426 00–WP 0435 00
Equipment Condition
Parking brake set and wheels chocked
(TM 9-2320-361-10).
Battery ground cable disconnected
(WP 0126 00).
Fuel burning personnel heater removed
(WP 0351 00).


Back to Top