60-AMPERE ALTERNATOR REPAIR (Contd)
ASSEMBLY (Contd)
16.
Install new O-ring (4), three negative rectifier leads (13), six positive rectifier leads (9), three
leads (20), and output plate (2) into end housing (5) with four screws (1).
17.
Apply silicone compound to negative rectifier plate (17).
18.
Install negative rectifier plate (17) on end housing (5) with two washers (16) and screws (15).
19.
Connect and solder three negative rectifier leads (13) to three negative rectifier terminals (14).
20.
Apply silicone compound to insulator (6) and positive rectifier plate (7).
21.
Install insulator (6) and positive rectifier plate (7) on end housing (5) with three nylon
washers (12), washers (11), and screws (10).
22.
Connect and solder six positive rectifier leads (9) to four positive rectifier terminals (8).
23.
Apply insulating compound to three rectifier terminals (14) and four rectifier terminals (8).
24.
Connect lead (18) to output plate stud (3).
25.
Install new tiedown strap (19) to three leads (20).