TM 9-2320-361-34
I
17-17. PERSONNEL HEATER OVERHEAT SWITCH AND RECEPTACLE REPLACEMENT (Contd)
c.
Receptacle Installation
1.
Install receptacle (15) on bracket (8) with four new screw-assembled
lockwashers
(l).
2. Install receptacle ground lead (14) on stud (9) with
nut (4).
3. Install leads (16) and (7) on flame detector switch (11) with new screw-assembled lockwashers (5)
and (6).
4. Install receptacle lead (12) on overheat switch (10) with new nut-assembled lockwasher (13).
5. Install restriction solenoid lead (3) on receptacle (15) with new screw-assembled lockwasher (2).
d. Overheat Switch Installation
1.
Install overheat
switch
(21)
on heater housing
(19)
with two screw-assembled lockwashers (20).
2. Install ignition control lead (25), thermostat lead (24), and receptacle lead (23) on overheat
switch (21) with new nut-assembled lockwasher (22).
3. Install shutoff valve lead (18) on overheat switch (21) with new nut-assembled lockwasher (17).
FOLLOW-ON TASK: Install personnel heater guard (para. 17-11).
17-46