TM-9-2320-362-14-P

TRUCK UTILITY: S250 SHELTER CARRIER, 4X4, M1037 FOR TRAFFIC JAM AN/TLQ-17A(V)3 (HMMWV)

TECHNICAL MANUAL; OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST FOR ELECTRICAL ENVIRONMENTAL SYSTEM (EES)

APRIL 1992

  TM-9-2320-362-14-P - Page 330 of 353

TM 9-2320-362-14&P
Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cent’d)
INSTRUCTIONS:
1.
2.
3.
4.
5.
6.
7.
a.
b.
Determine power cable part number needed from RPSTL and cut to
length as shown.
Cut the following heat shrink from bulk:
One 2 inch,
Two 3 inch, and
c.
Two 1 inch.
Select and install one terminal lug to cable end as shown.
Select and install proper heat shrink as shown (use gun type
heater P/N CV-5700)
Select and install proper electrical cable nipple as shown.
Select and install other terminal lug to cable end as shown.
Mark and install identification bands using old cable as
reference.
E-7


Back to Top