TM 9-2320-365-10
Change 2
3-70.17
Table 3-2.
Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
u6.
NO POWER TO SINGGAR/FORCE XXI BATTLE COMMAND BRIGADE AND BELOW
(FBCB)
Remove rings, bracelets, wristwatches, neck chains, and any other
jewelry before working around vehicle.
Jewelry may catch on
equipment or may short across an electrical circuit.
Failure to
comply
may result in serious injury or death to personnel.
Step (1).
Check to see if circuit breaker (CB8) is tripped.
(a)
Remove wing screw from power distribution shelf.
(b)
Loosen wing screw on electrical distribution block cover.
(c)
Remove electrical distribution block cover from power distribution shelf.
(d)
Check to see if circuit breaker (CB8) is tripped.
If circuit breaker (CB8) is tripped, push reset button in to reset.
If circuit breaker (CB8) trips again, notify Unit Maintenance.
WARNING