Table 3-2.
Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
u.
SPECIAL PURPOSE KIT (CONT)
u6.
NO POWER TO SINGGAR/FORCE XXI BATTLE COMMAND BRIGADE AND BELOW
(FBCB) (CONT)
Step (2).
Check to see if SINGGAR/Force XXI Battle Command Brigade and Below (FBCB) has power.
If SINGGAR/FBCB dos not have power, notify Unit Maintenance.
(a)
Position electrical distribution block cover on power distribution shelf.
(b)
Tighten wing screw on electrical distribution block cover.
(c)
Install wing screw on power distribution shelf.
u7.
NO POWER TO MOBILE TRACKING SYSTEM (MTS)
Remove rings, bracelets, wristwatches, neck chains, and any other
jewelry before working around vehicle.
Jewelry may catch on
equipment or may short across an electrical circuit.
Failure to
comply
may result in serious injury or death to personnel.
Step (1).
Check to see if circuit breaker (CB10) is tripped.
(a)
Remove wing screw from power distribution shelf.
(b)
Loosen wing screw on electrical distribution block cover.
(c)
Remove electrical distribution block cover from power distribution shelf.