TM 9-2320-365-20-1
Change 2
2-918.1
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
pneumatic controller connector pin D.
(3)
Connect negative (-) probe of multimeter to
pneumatic controller connector pin B and
note reading on multimeter.
(4)
If 30-80 ohms resistance is not present,
replace manifold valve assembly (para 12-7).
RESISTANCE TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
pneumatic controller connector pin F.
(3)
Connect negative (-) probe of multimeter to
pneumatic controller connector pin A and
note reading on multimeter.
(4)
If 30-80 ohms resistance is not present,
replace manifold valve assembly (para 12-7).
RESISTANCE TEST