TM-9-2320-365-20-1

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-1 - Page 1351 of 1760

TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
2-935
2-935
2-935
2-935
2-935
CONTINUITY TEST
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-R.
(3)
Connect negative (-) probe of multimeter to
connector P112-D and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS cable
assembly (para 7-53).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-F.
(3)
Connect negative (-) probe of multimeter to
connector P112-B and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS cable
assembly (para 7-53).
(5)
Connect connector P112 to manifold valve
assembly.


Back to Top