CONTINUITY TEST
CONTINUITY TEST
(1)
Disconnect connector P113 from manifold
valve assembly.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
connector P110-b.
(4)
Connect negative (-) probe of multimeter to
connector P113-B and note reading on
multimeter.
(5)
If continuity is not present, replace CTIS
cable assembly (para 7-53).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P110-c.
(3)
Connect negative (-) probe of multimeter to
connector P113-C and note reading on
multimeter.
(4)
If continuity is not present, replace CTIS cable
assembly (para 7-53).