e86.
11K SELF-RECOVERY WINCH DOES NOT REEL IN
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
References
TM 9-4910-571-12&P
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Materials/Parts
Wire, Elect, 50 ft (Item 77, Appendix D)
KNOWN INFO
1.
WARNING
Read WARNING
on following page.
START
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
YES
NO
Go to step 3 of this fault.
TM 9-2320-365-20-1
Is 24 VDC present on winch
in solenoid L4 connector
terminal 1?
Circuit breaker OK.
11K self-recovery winch pays
out.
POSSIBLE PROBLEMS
Faulty winch control valve
cable assembly.
Faulty winch control valve
assembly.
Faulty WINCH IN/OUT switch.
Faulty PTO cable assembly.
Faulty auxiliary panel cable
assembly.
2-946
Change 2