CONTINUITY TEST
Change 2
2-995
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P904-1.
(3) Connect negative (-) probe of multimeter to
connector P913-15 and note reading on
multimeter.
(4) If continuity is not present, repair wire 1904
(para 2-40) or replace auxiliary panel cable
assembly (all models except M1079 w/o
winch) (para 7-49).