TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
TM 9-2320-365-20-1
2-1057
2-1057
2-1057
2-1057
2-1057
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J31-15.
(3)
Connect negative (-) probe of multimeter to
connector J43-1 and note reading on multimeter.
(4)
If continuity is not present, repair wire 1403
(para 2-40) or replace engine control cable
assembly (para 7-72).