TM-9-2320-365-20-1

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-1 - Page 581 of 1760

CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX12A socket 2.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3020
from connector PX12A socket 2 to
connector PX14A socket 2 (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(5)
If continuity is present, repair wire 1908
from connector PX12A socket 1 to
connector PX17A socket 1 (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(6)
Connect connector PX12A to amber
warning light switch lamp base connector.
(7)
Install instrument panel assembly (para
7-15).
Change 1
2-376.11
TM 9-2320-365-20-1


Back to Top