TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 237 of 1432

TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1291
2-1291
2-1291
2-1291
2-1291
CONTINUITY TEST
(1)
Disconnect connector P245A from ROOM
THERMO connector.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
connector P245A pin A.
(4)
Connect negative (-) probe of multimeter to
connector J245 socket A and note reading on
multimeter.
(5)
Connect positive (+) probe of multimeter to
connector P245A pin B.
(6)
Connect negative (-) probe of multimeter to
connector J245 socket B and note reading on
multimeter.
(7)
Connect positive (+) probe of multimeter to
connector P245A pin C.
(8)
Connect negative (-) probe of multimeter to
connector J245 socket C and note reading on
multimeter.
(9)
If continuity is not present in step 4, 6, or 8,
replace M1079 heater thermostat cable (para
20-45).
(10)
Connect connector P245A to ROOM THERMO
connector.


Back to Top