(1)
Remove heater deflector/duct and hood
(para 20-50).
(2)
Disconnect connector J244A from heater
POWER RECEPTACLE connector.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector P244 pin A.
(5)
Connect negative (-) probe of multimeter to
connector J244A socket A and note reading on
multimeter.
(6)
Connect positive (+) probe of multimeter to
connector P244 pin C.
(7)
Connect negative (-) probe of multimeter to
connector J244A socket C and note reading on
multimeter.
(8)
Connect positive (+) probe of multimeter to
connector P244 pin D.
(9)
Connect negative (-) probe of multimeter to
connector J244A socket D and note reading
on multimeter.
(10)
If continuity is not present in step 5, 7, or 9,
replace M1079 heater power cable (para
20-50).
(11)
Connect connector J244A to heater POWER
RECEPTACLE connector.
CONTINUITY TEST