TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1341
2-1341
2-1341
2-1341
2-1341
CONTINUITY TEST
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
right output terminal of circuit breaker CB1.
(3)
Connect negative (-) probe of multimeter to
right input terminal of circuit breaker CB1 and
note reading on multimeter.
(4)
If continuity is not present, replace circuit
breaker CB1 (para 16-65).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
middle output terminal of circuit breaker CB1.
(3)
Connect negative (-) probe of multimeter to
middle input terminal of circuit breaker CB1 and
note reading on multimeter.
(4)
If continuity is not present, replace circuit
breaker CB1 (para 16-65).