TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 353 of 1432

CONTINUITY TEST
TM 9-2320-365-20-2
Change 1
2-1407
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector J119.
Refer to Table 2-22.
Main
Code 43 Sub Code 21 and 26 Low Side
Test Points.
(3) Connect negative (-) probe of multimeter to
connector J114 and note reading on
multimeter.
Refer to Table 2-22.
Main Code
43 Sub Code 21 and 26 Low Side Test
Points.
(4) Connect negative (-) probe of multimeter to
all other sockets in connector J114, one at a
time, and note reading on multimeter.
(5) Connect negative (-) probe of multimeter to
all sockets in connector J115, one at a time,
and note reading on multimeter.
(6) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(7) If continuity is not present in step 3, or
continuity is present in step 4, 5, or 6,
replace WTEC II cab transmission harness
(para 7-86).
Table 2-22.
Main Code 43 Sub Code 21 and 26 Low
Side Test Points
Sub
Code
Connector
J114
Connector
J119
21
26
1
H
A
10


Back to Top