CONTINUITY TEST
(1)
Remove two screws and cover from INTERIOR
LIGHTS switch S32 outlet box.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
K41 relay base terminal 6.
(4)
Connect negative (-) probe of multimeter to
top left pole of INTERIOR LIGHTS switch
S32 and note reading on multimeter.
(5)
If continuity is not present, repair or replace
wire 706C (para 2-40).
(6)
Close cover on relay box assembly.
(7)