CONTINUITY TEST
(1)
Remove six screws and cover from 110/208
VAC POWER DISTRIBUTION PANEL.
(2)
Remove circuit breaker CB6 from 110/208
VAC POWER DISTRIBUTION PANEL.
(3)
Position circuit breaker CB6 to ON.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter to
output terminal of circuit breaker CB6.
(6)
Connect negative (-) probe of multimeter to
input terminal of circuit breaker CB6 and note
reading on multimeter.
(7)
If continuity is not present, replace circuit
breaker CB6 (para 16-64).
(8)
Install circuit breaker CB6 on 110/208 VAC
POWER DISTRIBUTION PANEL.