TM 9-2320-365-20-3
(18) Position two screws (25) and self-locking nuts (26) in
spare tire retainer (2).
(19) Tighten two self-locking nuts (26) to 43-52 lb-ft (58-71
N·m).
WARNING
Hydraulic fluid (MIL-H-5606A) is TOXIC.
Wear protective goggles and gloves; use
only in well ventilated area; avoid contact
with skin,
eyes, and clothes. Skin and
clothing
that
come
in
contact
with
hydraulic
oil
should
be
washed
immediately.
Saturated clothing should
be
removed
immediately.
Failure
to
comply may result in injury to personnel.
NOTE
Install plastic cable ties as required.
(20) Connect two hydraulic hoses (27) to 90-degree fittings
(28).
14-33