TM 9-2320-365-20-5
20-244
Change 2
20-46.
M1079 HEATER FUEL TUBES/HOSES REPLACEMENT (CONT)
b. Installation.
(1)
Apply sealing compound to four-way fitting (1), 90-
degree fuel return (2), 90-degree fitting (3), and plug
(4).
(2)
Install 90-degree fuel return fitting (2), 90-degree fitting
(3), and plug (4) on four-way fitting (1).
(3)
Apply sealing compound to run tee fitting (5).
(4)
Install four-way fitting (1) on fuel tank (6).
NOTE
(5)
Connect fuel hose (7) to 90-degree return fitting (2).
(6)
Install run tee fitting (5) in auxiliary supply port (8).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing.
To avoid injury or death,
keep away from open fire and use in a
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap
and water. Failure to comply may result
in injury to personnel.
Install plastic cable ties as required.