VOLTAGE TEST
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
WARNING
CONTINUITY TEST
(1)
Set multimeter to volts dc.
(2)
Connect positive (+) probe of multimeter to
connector J106-E.
(3)
Connect negative (-) probe of multimeter to
ground.
(4)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(5)
If 12 vdc is not present, repair wire 1802
(para 2-45) or replace start and charging cable
assembly (para 7-132).
(6)
Position master power switch to off
(TM 9-2320-366-10-1).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J106-B.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3029
(para 2-45) or replace start and charging cable
assembly (para 7-132).