CONTINUITY TEST
(1)
Remove circuit breaker CB36 from PDP.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter
to relay K2 socket 87 on PDP.
(4)
Connect negative (-) probe of multimeter to
circuit breaker CB36 socket 6 on PDP and
note reading on multimeter.
(5)
If continuity is not present, repair wire
1604 from relay K2 socket 87 on PDP to
bus bar X6 on PDP (para 2-45) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable
assembly (para 7-11).
(6)
If continuity is present, replace bus bar X6
on PDP or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7)
Install circuit breaker CB36 in PDP.
(8)
Install relay K2 in PDP.
(9)
Install power distribution panel (PDP) cover
(para 16-2).
(10)
Connect batteries (para 7-57).