TM-9-2320-366-20-1

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-1 - Page 556 of 1824

e13. VOLTS GAGE DOES NOT OPERATE OR IS INACCURATE
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
NOTE
Perform electrical troubleshooting e1.
CIRCUIT BREAKER DOES NOT OPERATE
on circuit breaker CB77 prior to beginning
this task.
START
Is 24 VDC present on
connector PX10 pin 3?
WARNING
CAUTION
Read WARNING and
CAUTION on
following page.
1.
Go to step 3 of this fault.
NO
YES
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
KNOWN INFO
Circuit breaker CB77 OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty VOLTS gage.
TM 9-2320-366-20-1
2-356
Change 1


Back to Top