TM-9-2320-366-20-1

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-1 - Page 617 of 1824

TM 9-2320-366-20-1
CONTINUITY TEST
Change 1
2-386.9
(1)
Remove instrument panel for access (para
7-15).
(2)
Disconnect connector PX12A from amber
warning light switch lamp base connector.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
one terminal of lamp base connector.
(5)
Connect negative (-) probe of multimeter to
second terminal of lamp base connector and
note reading on multimeter.
(6)
If continuity is not present, replace rocker
switch lamp (para 7-18).
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.


Back to Top