TM 9-2320-366-20-1
TM 9-2320-366-20-1
TM 9-2320-366-20-1
TM 9-2320-366-20-1
TM 9-2320-366-20-1
2-530
2-530
2-530
2-530
2-530
1.
START
Other indicator lights
operate.
Is continuity present
through master stop
indicator lamps?
YES
NO
If continuity is not
present, master stop
indicator lamps are
faulty.
If continuity is
present, lighted indicator
display is faulty.
Faulty master stop
indicator lamps.
Faulty lighted indicator
display.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R #91
REASON FOR QUESTION
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B)
References
TM 9-4910-571-12&P
e40.
MASTER STOP INDICATOR DOES NOT OPERATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Batteries disconnected (para 7-57).
Personnel Required
(2)
Replace master stop indicator
lamps (para 7-16).
Replace lighted indicator
display (para 7-16).