TM-9-2320-366-20-1

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-1 - Page 823 of 1824

TM 9-2320-366-20-1
2-531
(1) Remove four screws from lighted indicator
display.
(2) Remove lighted indicator display from
instrument panel assembly.
(3) Disconnect connector PX7 from lighted
indicator display.
(4) Loosen four captive screws in lamp
mounting panel.
(5) Remove lamp mounting panel from lighted
indicator display housing.
(6) Remove master stop indicator lamps from
printed circuit board.
(7) Set multimeter to ohms.
(8) Check continuity through each master stop
indicator lamp and note reading on
multimeter.
(9) If continuity is not present, replace master
stop indicator lamps (para 7-16).
(10) If continuity is present, replace lighted
indicator display (para 7-16).
(11) Install master stop indicator lamps in
printed circuit board.
(12) Install lamp mounting panel in lighted
indicator display housing.
(13) Tighten four captive screws in lamp
mounting
panel.
CONTINUITY TEST
(14) Connect lighted indicator display to connector
PX7.
(15) Position lighted indicator display in instrument
panel assembly with four screws.
(16) Tighten four screws to 6-10 lb-in. (1 N·m).
(17) Connect batteries (para 7-57).


Back to Top