TM 9-2320-366-20-1
CONTINUITY TEST
CAUTION
(1)
Remove instrument panel assembly for
access (para 7-15).
(2)
Disconnect connector P18 from
connector J18.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter
to PDP terminal 86, where relay K7 was
removed.
(5)
Connect negative (-) probe of multimeter
to connector P18 pin 3 and note reading
on multimeter.
(6)
If continuity is not present, repair wire
16 from PDP relay K7 terminal 86 to
connector P18 pin 3 (para 2-45) or
replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7)
If continuity is present, repair wire 16
from connector P16 pin 3 to connector
PX15 socket M (para 2-45) or replace
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8)
Install relay K7 in PDP.
(9)
Install PDP cover (para 16-2).
Change 1
2-539
(10)
Connect connector P18 to connector J18.
(11)
Install instrument panel assembly
(para 7-15).
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
NOTE