KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
Operational Test
POSSIBLE PROBLEMS
Circuit breaker OK.
Vehicle starts.
PTO OK.
PTO switch OK.
PTO cable assembly OK.
Faulty WTEC II VIM.
Faulty WTEC II dashboard
cable assembly.
Faulty auxiliary panel
cable assembly.
Faulty WTEC II relay SF02.
Does PTO operate after
replacing WTEC II relay
SF02?
If PTO operates after
replacing WTEC II relay
SF02, WTEC II relay
SF02 is faulty. If
PTO does not operate
after replacing WTEC II
relay SF02, WTEC II VIM
is faulty.
7.
Replace WTEC II
VIM (para 8-6).