TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 211 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1087
2-1087
2-1087
2-1087
2-1087
CONTINUITY TEST
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
WTEC III relay K34 terminal 30.
(3)
Connect negative (-) probe of multimeter to
WTEC III relay K34 terminal 87a and note
reading on multimeter.
(4)
If continuity is not present, replace WTEC III
relay K34 (para 7-9).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
WTEC III relay K34 terminal 86.
(3)
Connect negative (-) probe of multimeter to
WTEC III relay K34 terminal 85 and note
reading on multimeter.
(4)
If continuity is not present, replace WTEC III
relay K34 (para 7-9).


Back to Top