TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 272 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1148
2-1148
2-1148
2-1148
2-1148
1.
START
YES
WARNING
Read WARNING
on following page.
NO
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
Go to step 3 of this fault.
This question eliminates
possible problems and
determines where
troubleshooting continues.
Is 24 vdc present on
connector P80B-2?
Air lines and fittings OK.
Air compressor
governor OK.
Dump up indicator OK.
POSSIBLE PROBLEMS
Faulty air dryer.
Faulty dashboard
cable assembly.
Faulty start and charging
cable assembly.
Faulty dump cable
assembly.
Voltage Test or
STE/ICE-R #89
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE


Back to Top