TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 274 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1150
2-1150
2-1150
2-1150
2-1150
YES
NO
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
2.
Is continuity present
from connector P80B-1
to ground?
If continuity is not present,
wire 3009 is faulty. If
continuity is present, air
dryer is faulty.
Air lines and fittings OK.
Air compressor
governor OK.
Dump up indicator OK.
Dashboard cable
assembly OK.
POSSIBLE PROBLEMS
Faulty air dryer.
Faulty start and charging
cable assembly.
Faulty dump cable
assembly.
Go to step 5 of this fault.
Continuity Test or
STE/ICE-R #91
Replace air dryer
(para 23-11).
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE (CONT)
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE (CONT)
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE (CONT)
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE (CONT)
e102.
M1090/M1094 AIR DRYER DOES NOT OPERATE (CONT)