TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1234
2-1234
2-1234
2-1234
2-1234
YES
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
6.
Notify DS Maintenance.
If continuity is not present,
remote control cable is
faulty.
POSSIBLE PROBLEMS
Faulty remote control
cable.
Other crane functions from
remote station OK.
Telescope in solenoid
cable OK.
Telescope in solenoid OK.
Remote control box
internal wiring harness OK.
TELESCOPE IN/OUT
controller OK.
External remote control
cable OK.
Is continuity present
from remote control
cable connector pin D to
terminal board lower
position 20?
NO
Replace remote control
cable (para 7-96).
e110.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM
e110.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM
e110.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM
e110.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM
e110.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM
REMOTE STATION (CONT)
REMOTE STATION (CONT)
REMOTE STATION (CONT)
REMOTE STATION (CONT)
REMOTE STATION (CONT)