TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 376 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1252
2-1252
2-1252
2-1252
2-1252
NO
YES
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
3.
This question eliminates
possible problems and
determines where to
continue troubleshooting.
Go to step 4 of this fault.
Go to step 5 of this fault.
POSSIBLE PROBLEMS
Other crane functions from
remote station OK.
Swing CW solenoid
cable OK.
Swing CW solenoid OK.
Faulty SWING CW/CCW
controller.
Faulty remote control
box internal wiring
harness.
Faulty external remote
control cable.
Faulty remote control
cable.
Is continuity present
from remote control box
connector pin L to pin N?
e112.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CW DOES NOT OPERATE FROM RE-
e112.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CW DOES NOT OPERATE FROM RE-
e112.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CW DOES NOT OPERATE FROM RE-
e112.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CW DOES NOT OPERATE FROM RE-
e112.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CW DOES NOT OPERATE FROM RE-
MOTE STATION (CONT)
MOTE STATION (CONT)
MOTE STATION (CONT)
MOTE STATION (CONT)
MOTE STATION (CONT)


Back to Top