2.
YES
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
Notify DS Maintenance.
Other crane functions from
remote station OK.
Remote control box OK.
SWING CW/CCW
controller OK.
Faulty swing CCW
solenoid cable.
Faulty swing CCW
solenoid.
If continuity is not present,
swing CCW solenoid
cable is faulty. If continuity
is present, swing CCW
solenoid is faulty.
Is continuity present
from swing CCW
solenoid cable
connector pin 2 to
ground and from pin 1
to terminal board lower
position 17?
NO
Replace swing CCW
solenoid cable (para 7-98).
e113.
M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE-