3.
Circuit breaker CB50 OK.
M1089 Material Handling
Crane operates.
All functions operate from
wrecker control panel.
Hydraulic functions OK.
Station selector
switch OK.
Wrecker control panel
wiring harness OK.
POSSIBLE PROBLEMS
Faulty wrecker remote
control wiring harness.
Is 24 vdc present at
pin C of J1 and/or J2?
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
If 24 vdc is not present,
wire 7 is faulty.
Repair wire 7 (para 2-45) or
replace wrecker control panel
wiring harness (para 7-83).
Perform Wrecker Pneumatic
Troubleshooting (aa1. All Wrecker
Functions Do Not Operate From
Wrecker Remote Control).
e137.