KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
9.
CAUTION
Read CAUTION
on following page.
YES
Continuity Test or
STE/ICE-R Test #91
NO
Repair wire 2006 from connector
P911 socket 3 to connector P909
socket 5 (para 2-45) or replace
auxiliary panel cable assembly
(para 7-58).
e144. M1090/M1094 DUMP BODY DOES NOT LOWER (CONT)
2-1502.4
Change 2
TM 9-2320-366-20-2
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
POSSIBLE PROBLEMS
Faulty auxiliary panel cable
assembly.
Faulty dashboard cable
assembly.
Is continuity present from
connector P911 socket 3 to
connector P909 socket 5?
If continuity is not present,
wire 2006 in auxiliary panel
cable assembly is faulty.