TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 684 of 1632

KNOWN INFO
REASON FOR QUESTION
YES
5.
WARNING
CAUTION
Read WARNING and
CAUTION on
following page.
Go to step 9 of this fault.
NO
Voltage Test or
STE/ICE-R Test #89
TEST OPTIONS
e144. M1090/M1094 DUMP BODY DOES NOT LOWER (CONT)
TM 9-2320-366-20-2
POSSIBLE PROBLEMS
Faulty DUMP BED UP/DOWN
switch.
Faulty auxiliary panel cable
assembly.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
power cable assembly.
Faulty dashboard cable
assembly.
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
Is 24 VDC present at
connector P911 socket 3?
If 24 VDC is not present, wire
2006 is faulty.
2-1498
Change 2


Back to Top