TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 678 of 1632

1.
WARNING
CAUTION
Read WARNING and
CAUTION on
following page.
TEST OPTIONS
REASON FOR QUESTION
YES
NO
Go to step 5 of this fault.
e144. M1090/M1094 DUMP BODY DOES NOT LOWER
KNOWN INFO
Voltage Test or
STE/ICE-R Test #89
Is 24 VDC present at
connector L9 socket 1?
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
References
TM 9-4910-571-12&P
This question eliminates
possible problems and
determines where
troubleshooting continues.
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Goggles, Industrial (Item 15, Appendix C)
Sling, Cargo (Item 31, Appendix C)
Lifting Bracket, Dump Body (2) (Item E-24, Appendix E)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Wire, Elec, 50 ft (Item 71, Appendix D)
TM 9-2320-366-20-2
POSSIBLE PROBLEMS
Faulty dump body hydraulic
system.
Faulty solenoid valve.
Faulty DUMP BED UP/DOWN
switch.
Faulty auxiliary panel cable
assembly.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
power cable assembly.
Faulty dashboard cable
assembly.
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
2-1492
Change 2
START
NOTE
Perform Electrical System Troubleshooting
e1. Circuit Breaker Does Not Operate on
circuit breaker CB50 prior to beginning
this task.


Back to Top