CONTINUITY TEST
CONTINUITY TEST
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
NOTE
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to terminal 1 on down solenoid.
(3)
Connect negative (-) probe of multimeter
to terminal 2 on down solenoid and note
reading on multimeter.
(4)
If continuity is not present, replace
solenoid valve (para 7-142).
(5)
If continuity is present, notify DS
Maintenance to perform Dump Body
Hydraulic
System troubleshooting task k2. Dump Body
Does Not Lower.
(6) Connect connector L9 to solenoid
valve.
(7) Tighten screw in connector L9.
Change 2
2-1495
TM 9-2320-366-20-2
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to connector L9 socket 2.
(3)
Connect negative (-) probe of multimeter
to ground and note reading on
multimeter.
(4)
If continuity is not present, go to step 4
of this fault.