KNOWN INFO
2.
TEST OPTIONS
REASON FOR QUESTION
CAUTION
Read CAUTION
on following page.
YES
3.
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
NO
Go to step 4 of this fault.
CAUTION
Read CAUTION
on following page.
Continuity Test or
STE/ICE-R Test #91
Continuity Test or
STE/ICE-R Test #91
This question eliminates
possible problems and
determines where
troubleshooting continues.
e144. M1090/M1094 DUMP BODY DOES NOT LOWER (CONT)
NO
Replace solenoid valve
(para 7-142).
YES
Notify DS Maintenance to perform Dump
Body Hydraulic System troubleshooting
task k2. Dump Body Does Not Lower.
TM 9-2320-366-20-2
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
DUMP BED UP/DOWN
switch OK.
Dashboard cable
assembly OK.
Auxiliary panel cable
assembly OK.
POSSIBLE PROBLEMS
POSSIBLE PROBLEMS
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
DUMP BED UP/DOWN
switch OK.
Dashboard cable
assembly OK.
Auxiliary panel cable
assembly OK.
M1090/M1094 dump
cable assembly OK.
M1090/M1094 dump power
cable assembly OK.
If continuity is present, dump
body hydraulic system is
faulty.
Is continuity present from
terminal 1 to terminal 2 on
down solenoid?
Is continuity present
from connector L9 socket 2
to a known good ground?
2-1494
Change 2
Faulty dump body hydraulic
system.
Faulty solenoid valve.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
power cable assembly.
Faulty dump body hydraulic
system.
Faulty solenoid valve.