KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
NO
10.
CAUTION
Read CAUTION
on following page.
YES
e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)
Continuity Test or
STE/ICE-R Test #91
2-1490.6
Change 2
TM 9-2320-366-20-2
POSSIBLE PROBLEMS
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
Faulty auxiliary panel cable
assembly.
Faulty dashboard cable
assembly.
Is continuity present from
connector P909 socket 5 to
connector J912 socket 1?
If continuity is not present,
wire 2006 in auxiliary panel
cable assembly is faulty.
If
continuity is present, wire
2006 in dashboard cable
assembly is faulty.
Repair wire 2006 from connector
P909 socket 5 to connector J912
socket 1 (para 2-45) or replace
auxiliary panel cable assembly
(para 7-58).
Repair wire 2006 from connector
P912 pin 1 to circuit breaker CB50
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).