TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 666 of 1632

KNOWN INFO
TEST OPTIONS
YES
5.
WARNING
CAUTION
Read WARNING and
CAUTION on
following page.
Voltage Test or
STE/ICE-R Test #89
Go to step 9 of this fault.
NO
e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)
Is 24 VDC present at
connector P911 socket 3?
TM 9-2320-366-20-2
2-1486
Change 2
POSSIBLE PROBLEMS
Faulty DUMP BED UP/DOWN
switch.
Faulty auxiliary panel cable
assembly.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
power cable assembly.
Faulty dashboard cable
assembly.
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
REASON FOR QUESTION
If 24 VDC is not present, wire
2006 is faulty.


Back to Top