KNOWN INFO
4.
TEST OPTIONS
REASON FOR QUESTION
CAUTION
Read CAUTION
on following page.
NO
YES
Continuity Test or
STE/ICE-R Test #91
e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)
Repair wire 3084 from connector
P172 socket H to terminal lug TL77
(para 2-45) or replace M1090/M1094
dump power cable assembly (para 7-125).
POSSIBLE PROBLEMS
TM 9-2320-366-20-2
Hydraulic oil level OK.
PTO OK.
Circuit breaker CB50 OK.
Auxiliary panel cable
assembly OK.
DUMP BED UP/DOWN
switch OK.
Dump body hydraulic
system OK.
Faulty M1090/M1094 dump
cable assembly.
Faulty M1090/M1094 dump
power cable assembly.
Repair wire 3084 from connector
J172 pin H to connector L8 socket 2
(para 2-45) or replace M1090/M1094
dump cable assembly (para 7-124).
If continuity is not present,
wire 3084 in M1090/M1094
dump power cable assembly
is faulty.
If continuity is
present, wire 3084 in M1090/
M1094 dump cable assembly
is faulty.
Is continuity present from
connector P172 socket H
to a known good ground?
2-1484