1.
START
YES
NO
KNOWN INFO
WARNING
Read WARNING
on following page.
Is 12 vdc present at
connector P906-5?
This question eliminates
possible problems and
determines where
troubleshooting continues.
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
Circuit breaker OK.
Worklights normal
mode OK.
POSSIBLE PROBLEMS
Faulty blackout override
switch.
Faulty dashboard cable
assembly.
Faulty auxiliary panel cable
assembly.
Faulty relay K12.
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
References
TM 9-4910-571-12&P
e151.
M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE IN BLACKOUT MODE WITH
BLACKOUT OVERRIDE SWITCH ON
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Materials/Parts
Wire, Elect, 50 ft (Item 71, Appendix D)
Go to step 3 of this fault.